Browse all practice questions for the National Contact Lens Registry Advanced Certification (NCLE-AC) Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

National Contact Lens Registry Advanced Certification (NCLE-AC) Practice Exam course image
A Careful Soft Contact Lens Fit Starts With Watching How It MovesIn performing a preliminary evaluation of soft contact lens movement, what should a technician observe?Corneal Infiltrates: Understanding Their Causes and Implications for Eye HealthWhat are corneal infiltrates a result of?Discover the Essential Layers of the Pre-Corneal Tear FilmWhat are the three layers of the classic pre-corneal tear film?Learn Why Isopropyl Alcohol Is a No-Go for Rigid LensesWhy should cleaners that contain isopropyl alcohol not be used on rigid lenses?Mastering the Art of Lens Insertion for a Perfect FitWhat should be avoided during lens insertion to ensure proper fit?Understanding Arcuate Stain and Its Implications for Contact Lens WearWhat is an arcuate stain in relation to contact lenses?Understanding Arcus Senilis in Elderly EyesWhat is the whitish haze in the peripheral corneal stroma often seen in the elderly?Understanding Blurred Vision After Blinking with Soft Contact LensesDuring a follow-up exam, a patient wearing soft lenses reports their vision is clear immediately after a blink and then blurs. What is the most likely cause?Understanding Contact Lens Movement and Comfort LevelsWhich statement concerning lens movement is not correct?Understanding FDA group I soft contact lenses: low water content and ionic surface characteristicsWhich characteristic defines FDA group I soft lenses?Understanding Irregular Astigmatism After Penetrating Keratoplasty SurgeryWhat type of astigmatism is likely to occur after Penetrating Keratoplasty surgery?Understanding Measurement Tools for Gas Permeable LensesWhich tool cannot be used to verify the overall gas permeable lens diameter?Understanding Optimal GP Lens Design for Astigmatism CorrectionGiven the K readings of 45.00 @ 180/42.00 @ 90, what is the optimal GP lens design for correcting this patient's vision?Understanding Over-Refraction and Lens Adjustments for Advanced CertificationIf an over-refraction on a gas permeable diagnostic lens results in Plano +1.50 X 95, what lens parameters might you order for the patient with the diagnostic lens of 43.50-2.00 9.2?Understanding Polymegathism and Its Impact on Corneal HealthWhat does polymegathism refer to?Understanding the Adjustments for Gas Permeable LensesTo steepen the lens-corneal relationship of a gas permeable lens, which adjustments should be made?Understanding the Behavior of Flat Lenses in Contact LensesWhat is a characteristic of flat lenses?Understanding the Importance of Proper GP Lens Insertion TechniquesPoor GP insertion or recentering techniques may result in which of the following?Understanding the Role of the -1.00 Auxiliary Lens in KeratometryWhich auxiliary lens is used to extend the keratometer range to approximately 30.00D?Understanding What the Slot Gauge Measures in Contact Lens FittingWhat does the slot gauge measure?Understanding What to Include in Medical Records for Contact Lens PatientsWhich document is NOT important to include in a medical record for contact lens patients?Understanding why horizontal meridian touch occurs when fitting high with-the-rule astigmatism with a spherical GP lensA patient with a high degree of with-the-rule astigmatism fitted with a spherical gas permeable lens will show touch?What it means when mires aren’t in focus on a radiuscope for a rigid contact lensWhat might it indicate if the mires are not in focus when verifying a rigid lens on a radiuscope?What to Look for When Your Contact Lens Seems Too SteepWhich of the following visual indicators suggests a lens is too steep?Why a warped contact lens has two curves and how that guides fittingHow many curves does a warped lens have?Why a warped rigid contact lens shows two curvatures but a single power on the lensometerA rigid lens shows two curves on the convex surface measured with radiuscope, but shows one power on the lensometer. What type of lens is this?Why Increasing the Optical Zone of Your Contact Lenses Can Enhance ComfortWhat effect does increasing the optical zone have on a contact lens?Why the lens shaping step matters for predictable fit in contact lensesWhat aspect of the manufacturing process can affect the predictability of fit in lenses?Why water content and center thickness cap Dk/t in older hydrogel lenses, and how silicone hydrogel changes the gameWhat limits the Dk/t of previous hydrogel lenses prior to silicone hydrogel lenses?
More practice questions

These questions are part of the practice quiz. Start practicing

  • How many curves does a front toric lens have?
  • If a patient has a refractive cylinder of 1.50D and keratometer readings of 44.00 @ 180/44.50 @ 90, what outcome would you expect from a spherical gas permeable lens?
  • What is the primary purpose of a soft toric lens?
  • Which of the following will NOT increase the movement of a tight fitting gas permeable lens?
  • The following RX represents which condition: OD+2.00= 20/20, OS-3.00-2.00X180=20/20?
  • Fitting soft lenses steeper than the K reading typically results in which of the following?
  • What does "in situ" mean when assessing contact lenses?
  • What technique is used to verify gross corneal edema with a slit lamp?
  • In the healing process of a graft, how does it function?
  • Which of the following describes the benefit of edge lift in a contact lens?
  • Which of the following could cause a patient rigid contact lens to displace frequently and pop out without a cause?
  • A rigid lens showing apical pooling is typically an indication of what type of fit?
  • What condition often requires special consideration when fitting contact lenses?
  • If Volk striae and microcysts are combined, what condition might this indicate?
  • For Carol, who is fitted with GP contact lenses on flat K and has a refraction of -5.00+2.00X 90, what is the effective power of her contact lenses?
  • What is the main supply of oxygen to the corneal epithelium derived from?
  • When adjusting the rotation for a toric lens that rotates halfway between 5 o'clock and 6 o'clock using the LARS principle, what adjustment is necessary?
  • Where does the base curve of a multi-focal contact lens generally align?
  • Which lens design would provide the best visual results for a prescription of RX -3.00 sphere?
  • What condition might an inability to bring all keratometer mires into focus indicate?
  • A rigid lens showing central vaulting is indicative of what?
  • What is a common characteristic of tear film abnormalities in aging?
  • Which of the following is NOT a cone type associated with Keratoconus?
  • Which lens specifications would best simulate a lid attachment rigid lens fitting for K's 42.00 @ 180/43.00 @ 90?
  • What is a common characteristic of an inverted or flat fitting lens?
  • What type of lens is indicated if a thickness gauge measures 0.73 mm on a rigid contact lens?
  • Which staining agent is best used for identifying degenerating endothelial cells?
  • On a compromised cornea, such as one that has undergone a corneal graft, which lens characteristic would be most beneficial?
  • What should a technician suspect if an adapted contact lens wearer complains of sudden onset of discomfort?
  • Punctal occlusion may be most beneficial for which of the following conditions?
  • Which auxiliary trial lens will extend the keratometer range to approximately 61.00D?
  • When should newly fitted extended wear patients have their first check-in?
  • If a lens rotates 10° to the left during a diagnostic evaluation, which parameter should be ordered for the patient?
  • What is the recommended method for inserting scleral lenses?
  • What is the acceptable tolerance for overall lens diameter according to ANSI standards?
  • When fitting a contact lens, what should be adjusted when moving from the spectacle plane to the corneal plane for prescriptions of 4.00 D or greater?
  • How do steep lenses behave once inserted?
  • What visual condition does a patient with a tight fitting lens typically report?
  • What typically triggers the onset of VLK?
  • How does radial keratoplasty primarily heal?
  • Which of the following tools is not used for blending peripheral curves in an office?
  • This patient with OD+2.00= 20/20 and OS-3.00-2.00X180=20/20 will best achieve stereopsis with which of the following modalities?
  • What is often the best indicator of systemic health issues related to contact lens wear?
  • What set of lens specifications would best simulate intrapalpebral GP fitting with K's of 42.00 @ 180/43.00 @ 90 and an RX of -2.00-1.00X 180?
  • To flatten the lens to cornea relationship in a gas permeable lens fit with parameters of 42.50-3.00 9.5, which lens should be ordered?
  • Why is the use of Wratten #12 or Tiffen yellow filter important in evaluating the fluorescence pattern of patients with GP lenses?
  • What characteristic is essential for therapeutic soft lenses?
  • What is the result of a lens having an aspheric design?
  • Which of the following is NOT an ocular sign of aging?
  • Which radius tool should be used to create a smooth blend between the intermediate and peripheral curve of a contact lens?
  • Which lens design is least likely to provide good visual results for a prescription of -2.50+1.50X90?
  • What is a disadvantage of using lathe cutting for lens production?
  • Dry eyes are a common side effect of which of the following medications?
  • When fitting a soft lens with a prescribed power, what must be considered in relation to the base curve?
  • If a lens is stated to have a "steep fit," what does that imply?
  • If a patient experiences discomfort and burning with soft contact lenses, what could be the likely issue?
  • If Mary has a base curve of 43.50D and a power of +2.75D on her gas permeable lens, what would be the new power required if the base curve changes to 43.00D?
  • Which condition is commonly associated with the aging process affecting lens flexibility?
  • Which design is appropriate for a patient requiring correction tо moderate astigmatism?
  • What does the pre-corneal tear film provide?
  • What is an essential characteristic of an ideal wetting solution?
  • Which of the following would NOT be a corrective action for a loose lens fit?
  • What type of contact lens adjustment could correct a situation where the lens is not providing adequate vision due to fitting?
  • After undergoing penetrating keratoplasty, which corneal layer does not regenerate?
  • Wearing lenses in high altitudes and dry environments may result in complaints of all but which of the following?
  • For a prism ballast GP lens, what is the required amount of prism for proper orientation?
  • When assessing a multifocal lens fit, what is the main consideration for the base curve?
  • If a contact lens is too loose, which adjustment can be made?
  • What is the recommended technique for removing RGP lenses that are stuck?
  • In topography, which colors signify a flatter terrain?
  • In routine cosmetic daily wear, how often should patients typically be evaluated?
  • For a patient with exophthalmic eyes needing a toric lens, which of the following is a concern?
  • Causes of lens flexure may include?
  • If a surface is excessively flat, how will the mires in the keratometer appear?
  • Which of the following modifications can enhance tear exchange on an RGP lens?
  • If a soft contact lens becomes adherent to the cornea, what should the patient do?
  • What instructions should patients receive to prevent their contact lenses from becoming contaminated?
  • What would be an appropriate response if a lens is causing discomfort?
  • What is the primary purpose of using a suction cup for RGP lens removal?
  • When evaluating tear film break up time, what is a concerning indicator for contact lens success?
  • What can cause discrepancies in keratometer readings?
  • Given an over refraction of -1.00-0.50X174 on a soft lens of 8.4-2.00 14.2, which parameters would you order for the patient?
  • What is the first step in checking a scleral lens fit?
  • How does endothelial dysfunction affect the lens?
  • If a soft lens exhibits edge lift when observed on a cornea, how can this be corrected?
  • What is the significance of non-preservative solutions for scleral lenses?
  • Given K' S 42.00 @ 180/45.00 @ 90 with an RX of -3.00-2.25X 180, which lens design would best correct the wearer's vision?
  • What typically causes microcysts in the cornea?
  • In which situation should a new lens fitting be considered?
  • In an alignment lid attachment GP fit, the fluorescein pattern should show what characteristic?
  • Which factor can lead to discomfort associated with rigid gas permeable lenses?
  • What does excessive staining at three and nine o'clock in GP lenses indicate?
  • What effect does a longer radius of curvature have on a contact lens?
  • Where do spherical equivalent powers position the image on the retina?
  • What is a common cause of lens discomfort during prolonged periods of reading with contact lenses?
  • Which type of RGP lenses are more likely to flex?
  • What is the best technique to evaluate the movement of a thin hydrogel lens?
  • A technician should look for which of the following signs when assessing lens movement?
  • What characteristic is vital for the healing process after radial keratoplasty?
  • In which direction does a GP lens typically orient when used for irregular astigmatism?
  • What problem might flat lenses cause during wear?
  • What is a common cause of SEAL (Superior Epithelial Arcuate Lesion)?
  • Given the patient's curvature readings of K's 42.00 @180 and 42.00 @90, which kind of contact lens is likely needed for optimum visual acuity?
  • After an over-refraction on soft lenses of 8.8-4.00 14.0 results in -0.75D sphere, which parameters would you order for the patient?
  • A patient has a horizontal visible iris diameter (HVID) of 12.5mm. What is the best choice of contact lens diameter?
  • Gas permeable lens flexure may be eliminated by which of the following methods?
  • In the case of observed corneal edema inferiorly under a prism ballast toric soft lens, what is the probable cause?
  • To increase movement on a diagnostic gas permeable lens with minimal movement, which adjustment would be effective?
  • Which type of contact lens is most beneficial for someone with recurrent corneal erosions?
  • Which statement about eye makeup is correct?
  • In terms of lens design, what defines a toric lens?
  • How is the optical zone calculated?
  • Based on K readings of 44.00 at 180/41.00 at 90 and Rx of -1.00-3.00X 90, which is the correct base curve and power?
  • For a patient with K's of 44.00 @ 180 and 46.50 @ 90, which special GP lens design would be most beneficial?
  • In which scenario is working with CNC most relevant?
  • What is the FDA classification of contact lens care products aimed at?
  • What is the method for checking for edema using a slit lamp?
  • A rigid lens showing a band shaped area of touch on the flattest meridian indicates which type of cornea?
  • Which of the following is a common recommendation for contact lens hygiene?
  • What instrument allows for simultaneous verification of lens diameter, optic zone, and peripheral curve?
  • Keratoconus and penetrating keratoplasty fittings are best accomplished by which of the following methods?
  • What diagnostic tool can aid in the early detection of Pellucid Marginal Degeneration?
  • Which layer of the cornea is primarily responsible for maintaining fluid balance and transparency?
  • The keratometer is an instrument used to measure what?
  • If a GP lens fails to provide acceptable visual acuity, what should the fitter first do?
  • What is the term for the loss of the crystalline lens's ability to accommodate?
  • Which of the following conditions would indicate the need for a lens with a thinner edge design?
  • Which lens manufacturing method is typically more costly?
  • If there is fluorescein touch at the intermediate curve of a lens, what should be done?
  • What modification cannot be performed in-office on RGP lenses?
  • How is disinfection defined in the context of contact lens care?
  • Extended wear contact lenses typically have a Dk/l value that is:
  • What type of lens measurement is affected by a change in the cornea's curvature?
  • What can occur if a patient improperly handles their contact lenses?
  • Which medication is known to affect successful contact lens wear?
  • What characteristic is associated with a lens described as having a steeper base curve?
  • What type of solution should be used in scleral lenses?
  • Prolonged contact lens wear without adequate blinking can lead to which of the following?
  • When prescribing contact lenses, what is a critical consideration for a patient's visual needs?
  • How many curves does a spherical lens contain?
  • How can one describe the lens shape of a spherical lens?
  • For a prescription of RX -3.50 -1.75 X 180 and K's of 42.00 @ 180 and 42.50 @ 90, what lens design would provide the best visual result?
  • Inferior punctate staining may indicate which condition?
  • Which situation may require increasing prism in bifocal lenses?
  • Which of the following is a translating bifocal lens design?
  • If a lens rotates 10° to the right during evaluation, which parameter adjustment might be necessary?
  • Which design feature enhances the stability of a myopic lens?
  • What is the primary function of the corneal endothelial cells?
  • What does pachymetry measure?
  • What is the primary benefit of using aspheric gas permeable lenses?
  • What condition may require immediate follow-up if a patient complains of pain and blurry vision after fitting contact lenses?
  • Which of the following is not a characteristic of corneal edema?
  • The first line of defense in the protective system of the eye is formed by which of the following?
  • If a rigid contact lens measures +15.00D BVP, what can be expected for the FVP measurement?
  • The role of preservatives in contact lens solution is to what?
  • What is the proper technique for removing scleral lenses?
  • What effect does long-term hypoxia have on the cornea?
  • If four hours of disinfection is recommended, what should a patient be advised?
  • Diffuse central punctate staining indicates the lens fit is likely:
  • For a patient with K's 45.00 @ 180/44.00 @ 90 and an RX of -3.00+1.00X 180, which lens specifications are best for an intrapalpebral GP fit?
  • Corneal microcysts are best visualized via biomicroscopy with which method of illumination?
  • What type of astigmatism is indicated by a fluorescein pattern showing a concentration of fluorescein inferiorly and superiorly beneath a rigid contact lens?
  • What prescription would be ordered for gas permeable lenses to fit on K's of 43.00 @ 180 and 44.00 @ 90 with RX -3.00 +1.00 X 90?
  • A rigid lens showing apical touch is an indication of?
  • What can excessive prism thickness lead to in an eye?
  • Tom's spectacles have a power of -12.00+0.50X 90. What would be the likely soft contact lens prescription for Tom?
  • Using the monovision technique for fitting spherical soft lenses, what is the desired power for the eye fitted for near with a prescription of RX -3.00-0.50 X 180, Add +1.25?
  • According to federal regulation, how long should a contact lens prescription be valid?
  • Which of the following corneal layers plays a crucial role in nutrient absorption?
  • Which feature is crucial for fitting high myopia patients with contact lenses?
  • If 3% generic hydrogen peroxide is substituted for the solution in one of the FDA approved hydrogen peroxide care systems, what may occur?
  • What does CNC stand for in the context of lenses and contact lens manufacturing?
  • What is the recommended approach if a high minus lens, such as -7, is riding high on the cornea?
  • To increase tear exchange on a RGP lens, which action is NOT recommended?
  • What type of ametropia frequently results in high riding rigid lenses?
  • When inspecting the blend on the bevel of a GP lens, what should be observed?
  • What is the purpose of a hyper flange in contact lens design?
  • What is the first step to take when measuring with a keratometer?
  • What is the type of bifocal lens that features a gradual change in power from the center to the periphery?
  • What condition on the eye is notably affected when corneal oxygen demand is not met?
  • What is a common result of long-term rigid contact lens wear?
  • How often should retraining for OSHA training on bloodborne pathogens occur?
  • How can three and nine o'clock staining in GP lenses be best eliminated?
  • An arcuate stain on the cornea in a GP wearer may be due to which factor?
  • How soon should patients wearing overnight contact lenses be seen for follow-up care?
  • What are the requirements of a good contact lens case?
  • What is the back vertex power of a lens measured when the concave side of a gas permeable lens is placed against the lens stop of the lensometer?
  • Which type of corneal astigmatism is GP lenses most indicated for?
  • Which of the following symptoms is consistent with corneal edema?
  • Which condition is associated with a decrease in accommodation?
  • What deficiency is commonly associated with mucin deficiency?
  • What type of microorganism is classified as gram negative?
  • What type of lens requires compensation for vertex distance when a prescription is 4.00 D or greater?
  • What is considered the best lens for patients with Keratoconus?
  • Which layers constitute the cornea?
  • What symptom might indicate a fitting issue with a contact lens?
  • What is a common sign of dry eye in contact lens wearers?
  • Which instrument is used for magnifying the edge of a rigid contact lens?
  • What needs to be considered when fitting lenses that are steeper than expected?
  • What is the ad power for a patient whose refraction shows best visual acuity at distance with a power of +1.25+1.00X 95?
  • What does the LARS principle assist with in contact lens fitting?
  • A non wetting gas permeable lens may cause?
  • The aqueous layer of the tear film is produced by which glands?
  • What does increased edge lift in a lens typically improve?
  • What could be a potential consequence of wearing a tight GP lens?
  • When evaluating a gas permeable lens fit, which characteristic should be increased to improve movement?
  • For a patient with K's of 46.00 @180/45.50 @90 and an RX of -3.00-1.50 X 90, which contact lens would best correct their visual needs?
  • Which lens condition might suggest a need to increase Dk levels?
  • To aid in the positioning of a gas permeable prism ballast lens that rides too low, which feature might be helpful?
  • Under what condition is it acceptable for a practitioner to withhold a contact lens prescription?
  • What modification could enhance comfort for patients with gas permeable lenses who experience foggy vision?
  • With the rule astigmatism features what type of curvature?
  • Fluorescein is used to observe all of the following except:
  • What are the characteristics of corneal edema?
  • What parameters should be ordered for Jill, who has a rigid lens with a base curve of 44.00D and a power of +3.00D sphere, requiring an over refraction of -0.50D and steepening the lens by 0.50D?
  • Transient keratometric mire distortion is usually due to what factor?
  • How does the front vertex power of a high plus lens compare to its back vertex power?
  • What visual effect is commonly noticed with corneal edema?
  • Slight pooling of fluorescence in the peripheral curve portion of a rigid lens indicates what?
  • Given K's readings of 44.00 @180 /45.25 @90 and an RX of -3.00+0.25x90, which type of lens would best suit the patient's visual needs?
  • How many curves does a bi-toric lens have?
  • Which of the following is a category of microorganism recognized by the FDA?
  • A toric soft lens is effective in correcting which type of astigmatism?
  • What edge design is recommended for a +15.00D aphakic gas permeable lens?
  • What is a notable outcome of the spin casting process in lens production?
  • When are bandage lenses typically indicated?
  • When fitting contact lenses, what is a crucial step to ensuring patient comfort?
  • What should be done if a contact lens appears to have deposits on it?
  • Which of the following best describes lenticular astigmatism?
  • What should be the primary concern if a patient experiences blurred vision after blinking?
  • What is one benefit of in-office polishing of a gas permeable lens?
  • What is a common side effect of antihistamines related to eye health?
  • What is the hardest curve to measure in contact lens fitting?
  • What condition should be suspected when there are larger fluctuations in a patient’s refractive error?
  • What is a common cause of mucin balls developing underneath contact lenses?
  • Which type of lens might require the use of a push-up technique to evaluate movement?
  • What is the normal tear break-up time in seconds?
  • Soft contact lenses are susceptible to deposits of?
  • What manufacturing process is most commonly used for disposable contact lenses?
  • How is lens flexure diagnosed?
  • When is the application of fluorescein best utilized?
  • What happens when a steep lens is too tight on the cornea?
  • In calculating the prescription for a rigid lens, what is the first step?
  • What does VLK stand for in contact lens terminology?
  • Why is it important to assess lens edge after checking GP lens fit?
  • Why should a soft lens never be fit with apical clearance?
  • What is the correct procedure for cleaning contact lenses according to recommended guidelines?
  • What causes mucin balls to form under contact lenses?
  • What term describes a sensitivity to light?
  • Improperly fitted contact lenses can lead to which ocular condition?
  • What is the primary purpose of contact lens care products?
  • What physiological effect might corneal infiltrates have on a patient?
  • Aqueous Tear Deficiency is primarily related to which disease?
  • Which type of contact lens is specifically designed for individuals with astigmatism?
  • The average lifespan of a corneal epithelium cell, from mitosis through maturation and desquamation, is approximately how long?
  • What type of lens would be recommended for a patient with a prescription of -3.00 sphere if they require a lens design that accommodates changes in prescription due to aging?
  • What primarily causes dimple veiling on the cornea?
  • What is a common consequence of a flat fitting gas permeable lens?
  • What is the average horizontal visible iris diameter (HVID) for a patient?
  • Which bifocal contact lens design may rotate without causing vision impairment?
  • What would be the first lens of choice for Mike, a welder with a prescription of -6.00+2.00 x 180, seeking more oxygen transmission to the cornea?
  • What feature is critical for assessing the peripheral fit of a lens?
  • When evaluating fluorescein patterns, a special filter must be used with?
  • Which type of astigmatism is represented by K's 42.50 @180 /40.50 @90?
  • What might be a concern when using certain lens solutions?
  • Where are the palisades of Vogt located?
  • How many diopters of power are required to focus parallel rays of light at a distance of 1 m?
  • In the case of central corneal haze, which method is typically used for assessment?
  • What is indicated if a rigid lens shows excessive edge lift?
  • What is the ideal eccentricity value for lenses?
  • If a patient has K readings of 43.50 @ 180 and 41.50 @ 90, what could be expected from a spherical GP lens?
  • What is the recommended follow-up schedule for new soft lens fits after the initial fit?
  • What is a key characteristic of good tear exchange in GP lenses?
  • What should be done for patients with a history of Giant Papillary Conjunctivitis (GPC) regarding lens fittings?
  • Which symptom is often associated with the use of a tight fitting lens?
  • What would be the required power of a soft contact lens for a patient with +8.50D spectacles sitting 12 mm from the cornea?
  • What is the purpose of the push-up test for contact lenses?
  • If a soft contact lens is not properly neutralized, how does the residual hydrogen peroxide affect the cornea?
  • Under what circumstance is it acceptable for a practitioner to withhold a contact lens prescription?
  • What does the FDA classification for disposable lenses signify?
  • What type of contact lens is recommended for a football player who primarily plays sports?
  • When determining the comfort of a contact lens fit, which factor is crucial?
  • Which condition is characterized by the inability to completely close the eyelids during sleep?
  • Where does VLK most commonly occur on the eye?
  • Which keratometer reading indicates with the rule astigmatism?
  • A lens fit characterized by apical touch indicates what type of corneal surface?
  • Which measurement is essential when fitting a rigid gas permeable lens?
  • What does ISO stand for in lens manufacturing?
  • What could potentially result from a tight fit of a contact lens?
  • Identify a primary characteristic of an aspheric lens.
  • Which instrument is used to obtain information about the cornea and surrounding structures?
  • Vogt's striae occur in which layer of the cornea?
  • Why is it important to avoid apical clearance in soft lens fitting?
  • What is classified as a contact lens blank?
  • What is a common characteristic of a soft spherical lens compared to other types?
  • Which type of contact lens is recommended for a patient with K's values of 43.00 @160 and 44.09 @75 experiencing 3+ distortion?
  • The Wratten filter is used with the biomicroscope to?
  • Why do contact lens technicians work with prescriptions in minus cylinder form?
  • The main purpose of a rigid lens wetting solution is to?
  • Which property is associated with a lens manufactured by spin casting?
  • When should therapeutic soft lenses be fit with minimal movement?
  • What does a Schirmer 1 test measure?
  • What is a key aspect of lathe cutting in contact lens production?
  • What pattern is associated with against the rule astigmatism?
  • The cornea receives nutrients primarily from which sources?
  • Which type of contact lens has 60% water content and is prone to deposits?
  • What are contact lenses that have a non-spherical back surface called?
  • What effect can poor insertion techniques have on the cornea?
  • If given K's of 42.50 @180 and 44.50 @90 with a prescription of -3.50-2.50X 90, what lens power should be ordered if the lenses are to be one half diopter steeper than K?
  • How can one evaluate a poorly finished transitional zone in a gas permeable lens?
  • What causes distortion immediately after a blink followed by clear mires when evaluating a soft lens?
  • Which of the following complications may arise from excessive dehydration of a toric lens in an exophthalmic patient?
  • Which method is used to evaluate corneal clearance in scleral lenses?
  • If keratometric miers are only clear when the wearer blinks, what can be inferred about the lens fit?
  • If a rigid lens was ordered with a base curve of 7.84 mm but received a lens measuring 7.94 mm, how does this lens compare to what was ordered?
  • Which of the following preservatives produces the least toxic response in the eye?
  • What is the acceptable tolerance for the power of a rigid lens that is under +/-5.00?
  • What tools are used for blending peripheral curves in the office?
  • A rigid lens showing excessive apical pooling is an indication of what type of fit?
  • For a patient with K readings of 42.50 @180 /42.50@90 and an Rx of 3.00 -1.00X90, which GP lens design is most appropriate?
  • A soft contact lens that is too loose may show all of the following except?
  • Which of the following activities should be discussed with patients wearing contact lenses?
  • What is the method for checking scleral lenses under fluorescein?
  • Which cold disinfection chemical is least likely to cause a reaction when used as directed?
  • Patients with keratitis sicca are more prone to which of the following?
  • What two design changes might be helpful in centering a high riding myopic lens?
  • Which bifocal design represents a translating design?
  • If an aphakic lens patient wears glasses, how might contact lenses change their vision?
  • What type of slit lamp illumination is typically utilized for observing tear break up time?
  • Which alteration would likely address an observed edge lift in a soft lens fitting?
  • What type of lens design includes prism ballast, double slab-off, and peri-ballast?
  • What is the primary function of the endothelial cell layer?
  • What is the first step toward resolution when corneal epithelial cells suffer trauma?
  • For which type of vision correction would a soft toric lens be most appropriate?
  • Which soft lens care system is most effective in the removal of deposits?
  • Which of the following are two methods of stabilizing the rotation of rigid bifocal contact lenses?
  • Which of the following factors will not improve lens stability in a soft toric lens?
  • What is the term for the condition characterized by the loss of vision without any apparent disease to the eye?
  • What does it mean when soft contact lenses must equilibrate on the eye?
  • What is the average pH value of human tears?
  • How many curves does a back toric lens contain?
  • To achieve optimal vision correction, what should be added to the HVID measurement?
  • Which of the following describes the base curve(s) that a warped lens will present?
  • When are soft lenses generally contraindicated?
  • To correct a flat fitting gas permeable lens, which option would be effective?
  • In against the rules astigmatism, where is the steepest corneal meridian typically located?
  • A warped lens will show how many base curves on the radiuscope and what type of power on the lensometer?
  • The slit lamp illumination that provides an overall view of the cornea but limits detail is:
  • What does a red/orange color represent in topography?
  • Which surface of the eye is the most powerful refractive surface?
  • How does a rigid lens correct astigmatism?
  • Which component is NOT part of the tear film?
  • What is the purpose of using polishing compound and radius tools in lens fitting?
  • Which modification to a gas permeable lens cannot be made in the office?
  • What type of astigmatism is represented by the following example: K's 44.00 @180/ 44.50 @90; RX -3.00 -2.50 X 180?
  • What type of slit lamp illumination helps to determine corneal thickening and depth of foreign bodies in the cornea?
  • Among the following, which method is used to decrease optic zone size?
  • What is a common characteristic of high-Dk/t lenses?
  • In lens manufacturing, what advantage does cast molding provide?
  • How does keratoplasty impact follow-up visits for patients wearing GP lenses?
  • Upon removal of the crystalline lens, the patient is described as which of the following?
  • What is a common effect of wearing contact lenses too long?
  • If a pre-presbyopic myopic patient is fit with contact lenses, what challenge might they face?
  • What type of astigmatism is commonly associated with aging?
  • Which is a potential side effect of improper lens fit?
  • Which structure is responsible for producing aqueous humor?
  • Which symptom is NOT associated with corneal edema?
  • What effect does decreasing the optical zone of a GP lens have?
  • What is the ANSI standard for GP thickness?
  • The measuring magnifier may be used to measure which of the following GP parameters?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy